Contact our team →TDC is a transverse joint system with a profile integral to the sheet metal. It is also flanged. Other systems use separate flanges, such as profiles or angle iron. The specification must identify the connection detail, its dimensions, sealing components and fasteners; the word “flanged” alone does not define the construction.
It is the nominal flange-profile height, not the sheet thickness. Assembly strength also depends on duct dimensions, pressure, thickness, reinforcement and supports. Corner pieces and clips must be compatible with the specified profile.
In spiral ducts, a strip of sheet metal forms the body with a helical seam. In rolled ducts, a sheet is curved to the required geometry and given the specified seam. Selection depends on material, dimensions and service conditions. A round shape alone does not identify the manufacturing process.
Selection considers moisture, temperature, corrosion, cleaning, particles and finish. Aluminum, galvanized steel, carbon steel and stainless steel have different characteristics. Provide the material specification and conditions of use for supply assessment; appearance or sheet price alone is not enough.
Thickness must be defined in the design together with pressure, dimensions, material, reinforcement and support spacing. To avoid ambiguity when purchasing, state the thickness in millimeters and the material specification, in addition to any gauge number.
Not on its own. Consumption depends on the system: airflow, pressure losses, fan, controls, insulation, leakage and operation. A properly sized layout and construction consistent with the design can reduce losses, but savings percentages require a technical comparison under defined conditions.
Insulation may be included in the specification and must be confirmed in the proposal. Specify its thermal or acoustic purpose, material, thickness, facing and application location. Condensation, vapor control, cleaning, reaction to fire and outdoor exposure must be considered. Thermal insulation and acoustic treatment are not automatically equivalent.
No. In SMACNA terminology, seal class identifies where sealing is required. Leakage class relates to the air-leakage limit under defined conditions. A letter stated without identifying the standard and criterion does not demonstrate system performance.
The requirement, extent and procedure must be defined in the design and contract. Where specified, the test must establish sections, assessed area, pressure and acceptance limit. Visual inspection, leakage testing and airflow balancing are different checks.
Not without assessing the application. Grease, corrosive gases, abrasive particles, high temperatures and smoke extraction may require specific construction, materials, protection and access. A solution suited to comfort air must not automatically be applied to an industrial process.
It depends on the application. The ABNT NBR 16401 series covers air-conditioning installations; NBR 14518 addresses professional kitchens and NBR 7256 air treatment in healthcare facilities. SMACNA publishes separate references for HVAC and industrial ducts. The designer must define the applicable document and edition.
There is no single service life that applies to every installation. Material, corrosion, temperature, environment, assembly, cleaning and maintenance affect durability. Periodic inspection must assess the actual condition of the ductwork. Warranty periods and conditions are those agreed in the supply contract.
Send drawings and quantities, system application, material, thickness, dimensions, pressure, temperature and connection type. State the project city, required delivery date and whether insulation, accessories or installation are needed. Projects and requests can be sent to [email protected].
Compare the same duct run at the same specified airflow, operating pressure and sealing requirements. Include components, freight, lifting and installation hours for each option. If a factory-made fitting saves a shift of on-site work, include both the difference in the fitting price and the labor saved. This gives the project engineer an estimated net saving to consider.
Top Dutos handles assembly and installation inquiries. Send the project, location and access conditions so the scope can be defined. The proposal must specify included accessories, insulation, access equipment, inspections, tests and documents.
Available materials can be found in Technical resources. For the TDC clip, open the 3D application model or download the PDF manual and the DWG (PT) drawing in Portuguese.
Send projects and quote requests to [email protected] or call or message us on WhatsApp at +55 11 2576-4555. To help us assess your request, identify your company, project and required product or service.
Send drawings, quantities, the project city and the required delivery date. Also specify materials and expected operating conditions.
Your guide hereYour guide at Top Dutos
I'm Bob. I can help you find products, answer questions and prepare your quote request.
I'm here in the right-hand corner whenever you need me.
Privacy and assistance: read the information about your data.